Nadifit: a novel single position pulse based diagnostic system
DOI:
https://doi.org/10.18203/2394-6040.ijcmph20233503Keywords:
Nadifit, Single position pulse measurement, TCM, Ayurveda, Pulse waveformAbstract
Both traditional Chinese medicine (TCM) and traditional ayurvedic medicine (TAM) rely on a system of radial pulse diagnostics to assess a patient's health. The doctor or practitioner should place all three fingers on the patient's wrist and feel the styloid processes to detect any changes in the radial pulse. However, finding medical professionals skilled in pulse diagnosis or nadipariksha is becoming increasingly challenging in the current and upcoming generation. One technological approach that could solve this issue once and for all would be to transform objective pulse diagnosis into a subjective process. To automate this procedure, however, three separate sensors must be constructed for three positions in order to capture pulse at varying pulse pressures, which increases the hardware complexity for consumer use. To simplify the process and ensure a correct diagnosis, this study presents an effort to create the smart portable system Nadifit, which takes a single pulse reading from the patient. A single pulse is all that's needed to identify distinctive organ patterns, which can then be analyzed to provide insight into potential health issues. Analogue signals are quantified with the help of a microphone, a transmitter, and a 32-bit microprocessor. The data is acquired with a precision of 10 bits and virtually no electronic or contaminating noise outside of the system. The computer receives the collected pulse signal and does time and frequency domain analysis of the Nadi patterns, shapes, and width to determine the presence of the three ayurveda doshas (Vata, pitta, and kapha) as well as Chinese organ patterns (such as Qi stagnation, yin deficiency, yang excess, etc.). The experimental results demonstrate the effectiveness of the suggested system in identifying dosha, making it highly tailored to the individual patient's health issue. It is also demonstrated that the pulse waveform demonstrates the desired fluctuations in relation to patient age, pressure applied to the sensing element and full vs. empty stomach. Comparisons of stiffness across age groups are also performed. Practitioners, vaidhyas, and medical professionals are used to verify the system's accuracy. Hence, we believe a larger segment of the general public will be able to make use of our technology.
References
Hu J, Liu B. The basic theory, diagnostic, and therapeutic system of traditional Chinese medicine and the Challenges they bring to statistics. Stat Med. 2012;31(7):602-5.
Chen YY, Chang RS, Jwo KW, Hsu CC, Tsao CP. A non-contact pulse automatic positioning Measurement system for traditional Chinese medicine. Sensors. 2015;15(5):9899-914.
Lee CT, Wei LY. Spectrum analysis of human pulse. IEEE Trans. Biomed Eng. 1983;BME-30(6):348-52.
Chu YW, Luo CH, Chung YF, Hu CS, Yeh CC. Using an array sensor to determine differences in pulse diagnosis—Three positions and nine indicators. Eur J Integr Med. 2014;6:516-23.
Zou CM, Jiang SH, Yan JJ, Guo R, Yan HX, Liu GP et al. Analysis of TCM Pulse Instrument Development Progress; World Scientific Publishing Co Pte Ltd.: Singapore. 2016;69-75.
Wang YQ. Progress and prospect of objectivity study on four diagnostic methods in traditional Chinese medicine. In Proceedings of the IEEE International Conference on Bioinformatics and Biomedicine Workshops, Hong Kong, China. 2010.
Malinauskas K, Palevicius P, Ragulskis M, Ostasevicius V, Dauksevicius R. Validation of noninvasive moems-assisted measurement system based on ccd sensor for radial pulse analysis. Sensors. 2013;13(4):5368-80.
Wu JH, Chang RS, Jiang JA. A novel pulse measurement system by using laser triangulation and a cmos image sensor. Sensors. 2007;7:3366-85.
LinWang YY, Sze WK, Bau JG, Wang SH, Jan MY, Hsu TL, Wang WK. The ventricular-arterial coupling system can be analyzed by the eigenwave modes of the whole arterial system. Appl Phys Lett. 2008;92:153901.
HyunDae H, Fox MD. No touch pulse measurement by optical interferometry. IEEE Trans Biomed Eng. 1994;41(1):1096-9.
Brougham P. Pulse diagnosis–a clinical guide Acupunct Med. 2008;26(2):123-4.
Jin W. My pulse exploration (in Chinese), China Press of Traditional Chinese Medicine. Beijing. 2014;138-46.
Luo JW, Guo SW, Cao SS. The construction of unsmooth pulse images in traditional chinese medicine based on wave intensity technology, Evid. Based Complement Alternat Med. 2016;2468254.
Lukman S, He Y, Hui SC. Computational methods for traditional chinese medicine: a survey. Comput. Methods Progr Biomed. 2007;88(3):283-94.
Li K, Zhang S, Yang L. Changes of arterial pulse waveform characteristics with gestational age during normal pregnancy. Sci Rep. 2018;8(1):15571.
Zhang Q, Zhou J, Zhang B. Graph based multichannel feature fusion for wrist pulse diagnosis, IEEE J. Biomed. Health Inform. 2020;10.1109/JBHI.2020.3045274.
Wang D, Zhang D, Lu G. Generalized feature extraction for wrist pulse analysis: from 1-D time series to 2-D matrix. IEEE J Biomed Health Inform. 2017;21(4):978-85.
Wang D, Zhang D, Lu G. An optimal pulse system design by multichannel sensors fusion. IEEE J Biomed Health Inform. 2016;20(2):450-9.
Zhang Z, Zhang Y, Yao L, Song H, Kos A. A sensor-based wrist pulse signal processing and lung cancer recognition. J Biomed Inform. 2018;79:107-16.
Chen YY, Chang RS. A study of new pulse auscultation system. Sensors. 2015;15(4):8712-31.
Sharma P, Imtiaz SA, Rodriguez-Villegas E. Acoustic sensing as a novel wearable approach for cardiac monitoring at the wrist. Sci Rep. 2019;9(1):20079.
Will C, Shi K, Schellenberger S. Radar-based heart sound detection. Sci Rep. 2018;8(1):11551.
Yoon Y, Lee M, Soh K. Pulse type classification by varying contact pressure. IEEE Engineering in Medicine Biol Magazine. 2000;1(19):106-10.
Millasseau SC, Ritter JM, Takazawa K, Chowienczyk PJ. Contour analysis of the photoplethysmographic pulse measured at the finger. J Hypertens Aug. 2006;24(8):1449e56.
Venkata GKP, Sudheer D, Aniruddha J, Pooja M, Nagendra HR. Significance of arterial stiffness in Tridosha analysis: A pilot study. J Ayurveda Integrative Med. 2017;8(4):252-6.